16 Modbus
®
Mapping Assignments for Micro Motion
®
Transmitters
Modbus Mapping Assignments continued
4 1124 Display variable #8
ÖÖ
4 1125 Display variable #9
ÖÖ
4 1126 Display variable #10
ÖÖ
4 1127 Display variable #11
ÖÖ
4 1128 Display variable #12
ÖÖ
4 1129 Display variable #13
ÖÖ
4 1130 Display variable #14
ÖÖ
4 1131 Display variable #15
ÖÖ
4 1132 RS-485 digital communication protocol setting AIO
ÖÖ
4 1133 RS-485 digital communication baud rate AIO
ÖÖ
4 1134 RS-485 digital communication parity setting AIO
ÖÖ
4 1135 RS-485 digital communication stop bits setting AIO
ÖÖ
4 1139 Sensor type code
ÖÖ
4 1144 Polling control code #2
ÖÖ
4 1145 Polled variable #1 code
ÖÖ
4 1146 Polled variable #2 code
ÖÖ
4 1147 Polling type code
5
ÖÖ
4 1151 Discrete output 1 assignment
ÖÖ
4 1153 Discrete output 2 assignment
6
Ö
4 1164 100 Hz update rate variable assignment
ÖÖ
4 1165 Burst command
ÖÖ
4 1166 Output channel A type assignment
ÖÖ
4 1167 Output channel B type assignment
ÖÖ
4 1168 Output channel C type assignment
ÖÖ
4 1169 Burst variable 1
ÖÖ
4 1170 Burst variable 2
ÖÖ
4 1171 Burst variable 3
ÖÖ
4 1172 Burst variable 4
ÖÖ
4 1174 Channel B power
3
Ö
4 1175 Channel C power
5
Ö
4 1176 Discrete input 1 assignment
8
Ö
4 1181 Frequency output mode
5
Ö
4 1182 Discrete output 1 fixed value
ÖÖ
4 1183 Discrete output 2 fixed value
5
Ö
4 1186 Profibus station address (0-126)
7
Ö
4 1187
8
Core processor HART device I.D. number – high order register of
3-byte integer
ÖÖ
4 1188 Core processor HART device I.D. number – low order register of
3-byte integer
ÖÖ
4 1197 Frequency output polarity (0=active low, 1=active high)
ÖÖ
1
Supported in software even if associated output is not available.
2
Transmitters with intrinsically safe output boards or configurable input/output boards only.
3
Modbus or HART polling address (Version 3.6 or lower RFT9739 transmitter); HART polling address (Version 3.7 or higher
RFT9739 transmitter and Series 1000 and 2000 transmitters).
4
Version 3.7 or higher revision RFT9739 transmitter.
5
Release 2.x or lower only.
6
Transmitters with configurable input/output boards only.
7
Transmitters with Profibus-PA software only.
8
Must be queried through transmitter. Same as registers 31187-31188. If these registers contain a non-zero value. they are read-
only. If they contain 0, they can be written to.