Micro Motion®F-Series SensorInstallation ManualInstallation ManualP/N 20002298, Rev. AApril 2005
10 Sensor Installation: F-SeriesBefore You Begin Figure 7 Model F300A sensor with flexible conduit extended junction box Junction boxFlow direction ar
Sensor Installation: F-Series 11Determining a LocationStep 1 Determining a LocationChoose a location for the sensor based on the requirements describe
12 Sensor Installation: F-SeriesDetermining a Location Environmental limitsThe maximum ambient temperature for the sensor depends on the electronics o
Sensor Installation: F-Series 13Determining a LocationMaximum wiring distancesThe maximum distance between the sensor and transmitter depends on cable
14 Sensor Installation: F-SeriesOrienting the Sensor Step 2 Orienting the SensorThe sensor will function properly in any orientation if the sensor tub
Sensor Installation: F-Series 15Mounting the SensorStep 3 Mounting the SensorUse your common practices to minimize torque and bending load on process
16 Sensor Installation: F-SeriesMounting the Sensor Figure 11 Mounting the Model F300A electronics Mounting bracket (wall mount)Use 4 × 5/16″ (8 mm) b
Sensor Installation: F-Series 17WiringStep 4 WiringHazardous area installationsIf you are installing the sensor in a hazardous location, verify that t
18 Sensor Installation: F-SeriesWiring Core processor to a 4-wire remote transmitterFollow the steps below to connect the 4-wire cable between the cor
Sensor Installation: F-Series 19WiringFigure 13 Wrapping the shield drain wirese. Place the shielded heat shrink over the exposed shield drain wire(s)
2 Sensor Installation: F-SeriesBefore You Begin Before You Begin This manual describes how to install a Micro Motion® F-Series sensor. The following i
20 Sensor Installation: F-SeriesWiring Figure 16 Gland body and core processor housing5. Insert the wires through the gland body and assemble the glan
Sensor Installation: F-Series 21GroundingJunction box to a 9-wire remote transmitter or remote core processorFollow the steps below to connect the 9-w
22 Sensor Installation: F-SeriesPurge Fittings Purge FittingsIf the sensor has purge fittings, they should remain sealed at all times. After a purge p
Sensor Installation: F-Series 23Purge Fittings4. Connect the supply of nitrogen or argon gas to the inlet purge connection or open inlet purge line. L
24 Sensor Installation: F-SeriesReturn Policy Return PolicyMicro Motion procedures must be followed when returning equipment. These procedures ensure
© 2005 Micro Motion, Inc. All rights reserved. P/N 20002298, Rev. A*20002298*For the latest Micro Motion product specifications, view the PRODUCTS sec
Sensor Installation: F-Series 3Before You BeginEuropean installationsThis Micro Motion product complies with all applicable European directives when p
4 Sensor Installation: F-SeriesBefore You Begin Figure 1 F-Series sensor with core processorApproval tagFlow direction arrowCore processor housingCali
Sensor Installation: F-Series 5Before You BeginFigure 2 F-Series sensor with integrally mounted Model 1700/2700 transmitter Model 1700 or 2700 transmi
6 Sensor Installation: F-SeriesBefore You Begin Figure 3 F-Series sensor with junction boxJunction boxApproval tagFlow direction arrowApproval tagProc
Sensor Installation: F-Series 7Before You BeginFigure 4 F-Series sensor with integrally mounted IFT9701 transmitter Calibration tagFlow direction arro
8 Sensor Installation: F-SeriesBefore You Begin Figure 5 Model F300A sensor with flexible conduit extended core processor Flow direction arrowCore pro
Sensor Installation: F-Series 9Before You BeginFigure 6 Model F300A sensor with flexible conduit extended Model 1700/2700 transmitter Model 1700 or 27