Emerson Micro Motion F-Series Sensor Manuale di Installazione

Navigare online o scaricare Manuale di Installazione per Sistemi di controllo di accesso Emerson Micro Motion F-Series Sensor. Emerson Micro Motion F-Series Sensor Installation manual [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 26
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Micro Motion
®
F-Series Sensor
Installation Manual
Installation Manual
P/N 20002298, Rev. A
April 2005
Vedere la pagina 0
1 2 3 4 5 6 ... 25 26

Sommario

Pagina 1 - F-Series Sensor

Micro Motion®F-Series SensorInstallation ManualInstallation ManualP/N 20002298, Rev. AApril 2005

Pagina 2

10 Sensor Installation: F-SeriesBefore You Begin Figure 7 Model F300A sensor with flexible conduit extended junction box Junction boxFlow direction ar

Pagina 3

Sensor Installation: F-Series 11Determining a LocationStep 1 Determining a LocationChoose a location for the sensor based on the requirements describe

Pagina 4

12 Sensor Installation: F-SeriesDetermining a Location Environmental limitsThe maximum ambient temperature for the sensor depends on the electronics o

Pagina 5

Sensor Installation: F-Series 13Determining a LocationMaximum wiring distancesThe maximum distance between the sensor and transmitter depends on cable

Pagina 6

14 Sensor Installation: F-SeriesOrienting the Sensor Step 2 Orienting the SensorThe sensor will function properly in any orientation if the sensor tub

Pagina 7

Sensor Installation: F-Series 15Mounting the SensorStep 3 Mounting the SensorUse your common practices to minimize torque and bending load on process

Pagina 8

16 Sensor Installation: F-SeriesMounting the Sensor Figure 11 Mounting the Model F300A electronics Mounting bracket (wall mount)Use 4 × 5/16″ (8 mm) b

Pagina 9

Sensor Installation: F-Series 17WiringStep 4 WiringHazardous area installationsIf you are installing the sensor in a hazardous location, verify that t

Pagina 10 - Before You Begin

18 Sensor Installation: F-SeriesWiring Core processor to a 4-wire remote transmitterFollow the steps below to connect the 4-wire cable between the cor

Pagina 11 - Step 1 Determining a Location

Sensor Installation: F-Series 19WiringFigure 13 Wrapping the shield drain wirese. Place the shielded heat shrink over the exposed shield drain wire(s)

Pagina 12 - Determining a Location

2 Sensor Installation: F-SeriesBefore You Begin Before You Begin This manual describes how to install a Micro Motion® F-Series sensor. The following i

Pagina 13

20 Sensor Installation: F-SeriesWiring Figure 16 Gland body and core processor housing5. Insert the wires through the gland body and assemble the glan

Pagina 14 - Step 2 Orienting the Sensor

Sensor Installation: F-Series 21GroundingJunction box to a 9-wire remote transmitter or remote core processorFollow the steps below to connect the 9-w

Pagina 15 - Step 3 Mounting the Sensor

22 Sensor Installation: F-SeriesPurge Fittings Purge FittingsIf the sensor has purge fittings, they should remain sealed at all times. After a purge p

Pagina 16 - Mounting the Sensor

Sensor Installation: F-Series 23Purge Fittings4. Connect the supply of nitrogen or argon gas to the inlet purge connection or open inlet purge line. L

Pagina 17 - Step 4 Wiring

24 Sensor Installation: F-SeriesReturn Policy Return PolicyMicro Motion procedures must be followed when returning equipment. These procedures ensure

Pagina 19

© 2005 Micro Motion, Inc. All rights reserved. P/N 20002298, Rev. A*20002298*For the latest Micro Motion product specifications, view the PRODUCTS sec

Pagina 20

Sensor Installation: F-Series 3Before You BeginEuropean installationsThis Micro Motion product complies with all applicable European directives when p

Pagina 21 - Step 5 Grounding

4 Sensor Installation: F-SeriesBefore You Begin Figure 1 F-Series sensor with core processorApproval tagFlow direction arrowCore processor housingCali

Pagina 22 - Purge Fittings

Sensor Installation: F-Series 5Before You BeginFigure 2 F-Series sensor with integrally mounted Model 1700/2700 transmitter Model 1700 or 2700 transmi

Pagina 23

6 Sensor Installation: F-SeriesBefore You Begin Figure 3 F-Series sensor with junction boxJunction boxApproval tagFlow direction arrowApproval tagProc

Pagina 24 - Return Policy

Sensor Installation: F-Series 7Before You BeginFigure 4 F-Series sensor with integrally mounted IFT9701 transmitter Calibration tagFlow direction arro

Pagina 25

8 Sensor Installation: F-SeriesBefore You Begin Figure 5 Model F300A sensor with flexible conduit extended core processor Flow direction arrowCore pro

Pagina 26 - *20002298*

Sensor Installation: F-Series 9Before You BeginFigure 6 Model F300A sensor with flexible conduit extended Model 1700/2700 transmitter Model 1700 or 27

Commenti su questo manuale

Nessun commento