May 2015
30
Quick Start Guide
3. Intrinsically safe parameters:
4. The product should be used with Ex-certified associated apparatus to establish
explosion protection system that can be used in explosive gas atmospheres.
Wiring and terminals should comply with the instruction manual of the
product and associated apparatus.
5. The cable between this product and associated apparatus should be shielded
cables (the cables must have insulated shield). The shield has to be grounded
reliably in non-hazardous area.
6. The product complies to the requirements for FISCO field devices specified in
IEC60079-27:2008. For the connection of an intrinsically safe circuit in
accordance FISCO model, FISCO parameters of this product are as above.
7. End users are not permitted to change any components inside, but to settle
the problem in conjunction with manufacturer to avoid damage to the
product.
8. When installation, use and maintenance of this product, observe the following
standards:
GB3836.13-1997 “Electrical apparatus for explosive gas atmospheres Part 13:
Repair and overhaul for apparatus used in explosive gas atmospheres
GB3836.15-2000 “Electrical apparatus for explosive gas atmospheres Part 15:
Electrical installations in hazardous area (other than mines)”
GB3836.16-2006 “Electrical apparatus for explosive gas atmospheres Part 16:
Inspection and maintenance of electrical installation (other than mines)”
GB50257-1996 “Code for construction and acceptance of electric device for
explosion atmospheres and fire hazard electrical equipment installation
engineering”
N3 China Type n
Certificate: 3051S: GYJ101112X [Mfg China]
3051SF: GYJ101125X [Mfg China]
Standards: GB3836.1-2000, GB3836.8-2003
Markings: Ex nL IIC T5
Special Conditions for Safe Use (X):
1. Symbol “X” is used to denote specific conditions of use: The apparatus is not
capable of withstanding the 500V test to earth for one minute. This must be
taken into consideration during installation.
2. The ambient temperature range is: -40 °C
T
a
70 °C.
Output
code
Housing
code
Display
code
Maximum
input
voltage:
U
i
(V)
Maximum
input
current:
I
i
(mA)
Maximum
input power:
P
i
(W)
Maximum
internal
parameter:
C
i
(nF)
Maximum
internal
parameter:
L
i
(uH)
A =00 / 30 300 1 38 0
A 00 / 30 300 1 11.4 2.4
A 00 M7/M8/M9 30 300 1 0 58.2
F 00 / 30 300 1.3 0 0
F
FISCO
00 / 17.5 500 5.5 0 0
4801_QIG_RevMA.fm Page 30 Wednesday, May 6, 2015 1:15 PM