Quick connect wiring (if applicable)
As standard, the 3051S Quick Connect arrives properly assembled to the sensor
module and is ready for installation. Cordsets and field wireable connectors (in
shaded area) are sold separately.
Figure 10. Rosemount 3051S Quick Connect Exploded View
Important
If Quick Connect is ordered as a 300S spare housing or is removed from the sensor module, follow
the instructions below for proper assembly prior to field wiring.
1. Place the Quick Connect onto the sensor module. To ensure proper pin
alignment, remove coupling nut prior to installing quick connect onto the
sensor module.
2. Place coupling nut over quick connect and wrench tighten to a maximum of
300 in-lb. (34 N-m).
3. Tighten the set screw up to 30 in-lbs using a
3
/32-in. hex wrench.
4. Install cordset/field wireable connectors onto the Quick Connect.
Do not over tighten.
A. Straight field wireable connector
(1)
(
4
)
1.Order part number 03151-9063-0001.
D. Cordset
(2)
2. Supplied by cordset vendor.
B. Right angle field wireable connector
(3)(4)
3. Order part number 03151-9063-0002.
4. Field wiring supplied by customer
E. Coupling nut
C. Quick Connect housing F. Quick Connect coupling nut