Emerson Micro Motion F-Series Sensor Manuale di Installazione Pagina 10

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 20
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 9
Feedthrough and extender componentsFigure 2-2:
A
B
C
D
E
F
G
H
A. Transmitter or core processor
B. Extender
C. Plastic plug
D. Plastic cap
E. O-ring
F. Clamping ring
G. Clamping screw
H. Feedthrough
2. Loosen the clamping screw and remove the clamping ring. Leave the O-ring in place
on the feedthrough.
3. Remove and recycle the plastic plug from the extender.
4. Fit the extender onto the feedthrough by carefully aligning the notches on the
bottom of the extender with the notches on the feedthrough.
5. Close the clamping ring and tighten the clamping screw to 13–18 in-lbs.
(1,5–2 N-m).
Mounting
6 Micro Motion F-Series
Vedere la pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 19 20

Commenti su questo manuale

Nessun commento