Product Data SheetPDS 106-300NX.A01World Class 3000 November, 2000Visit our website at www.processanalytic.comOn-line ordering available. CENELEC
Page 10CENELEC CERTIFIED WORLD CLASS 3000 WITH SAFE AREA IFTELECTRONICS — ORDERING INFORMATION (continued)(Cont’d)Code IFT 3000 Style11 Blind IF
Page 11WORLD CLASS 3000 MULTIPROBE APPLICATION WITH CONTROLROOM ELECTRONICS (For Multi-Probe Applications)CRE 3000 Control Room Electronics M
Page 12CRE 3000 CONTROL ROOM ELECTRONICSAmbient environment requirements: Clean, DryAmbient temperature range: 4° to 120°F (4° to 50°C)Vibrati
Page 13CENELEC CERTIFIED WORLD CLASS 3000 WITH CONTROL ROOMELECTRONICS — ORDERING INFORMATION3001NCXCENELEC Certified World Class 3000 Oxygen An
Page 14CENELEC CERTIFIED WORLD CLASS 3000 WITH CONTROL ROOMELECTRONICS ORDERING INFORMATION (CONTINUED)Special sensing cells are available for
Page 15CENELEC CERTIFIED DIRECT REPLACEMENT PROBE UPGRADEPACKAGE — ORDERING INFORMATION3001DRXDirect Replacement CENELEC Certified World Class 3
Page 16WORLD CLASS 3000 ACCESSORIESHPS 3000 FIELD INTERFACE ELECTRONICSÀÀ[For use with CRE 3000 or optional with IFT 3000 for probe electronics di
Page 17WORLD CLASS 3000 ACCESSORIES (Continued)MPS 3000 MULTIPROBE TEST GAS SEQUENCER (OPTIONAL)ÀÀHousing classification: NEMA 4X (IP65)Humidity
Page 18WORLD CLASS 3000 ACCESSORIES (Continued)O2 Test Gas KitsRosemount Analytical’s O2 Test Gas and Service Kits have been carefullydesigned to prov
Page 2THE WORLD CLASS 3000 OXYGEN ANALYZER IS COMPLETELY FIELDREPAIRABLEDiffusion Element Assembly Sensor Cell Assembly Heater Thermocouple AssemblyOX
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they ar
Page 3WORLD CLASS 3000 OXYGEN ANALYZER DIMENSIONSOXYGEN PROBEÀÀHousing classification: CENELEC EExd IIB T1 (370)Probe lengths, nominal: 18 in. (
Page 4WORLD CLASS 3000 ELECTRONICS CONFIGURATIONSA World Class 3000 analyzer package typically includesan oxygen sensing probe, signal conditionin
Page 5FEATURES• Probe heater over-temperature protection uses softwareand hardware disable. With HPS 3000, hardware disablerequires optional cable.• O
Page 6IFT 3000 INTELLIGENT FIELD TRANSMITTERHousing classification: CENELEC EExd IIB T6Humidity range: 95% Relative HumidityAmbient temperature
Page 7CENELEC CERTIFIED WORLD CLASS 3000 WITH CENELEC-CERTIFIED IFTELECTRONICS — ORDERING INFORMATION3002NFXCENELEC Certified World Class 3000 Ox
Page 8CENELEC CERTIFIED WORLD CLASS 3000 WITH CENELEC-CERTIFIED IFTELECTRONICS — ORDERING INFORMATION (continued)(Cont’d)Code IFT 3000 Style EEx
Page 9CENELEC CERTIFIED WORLD CLASS 3000 WITH SAFE AREA IFTELECTRONICS — ORDERING INFORMATION3001NFXCENELEC Certified World Class 3000 Oxygen Ana