Product Data Sheet
PDS 106-300NX.A01
World Class 3000 November, 2000
Visit our website at www.processanalytic.com
On-line ordering available.
CENELEC Certified In Situ Oxygen
Analyzer Packages for Hazardous Area
Applications
CENELEC certification – EExd II B T1/T6
Completely field repairable probe
Field-replaceable cell and
heater/thermocouple design
Patented electronic cell protection
Rugged 316 SS for all wetted parts
HART
®
Communications Protocol provides
calibration and troubleshooting capability
from the control room.
Flexible electronics configuration
Easy calibration
No potentiometers to adjust
For use in refineries, petrochemical plants,
and all areas classified zone 1
WORLD CLASS TECHNOLOGY
FROM THE WORLD LEADER
The Hagan in situ, zirconium oxide oxygen analyzer has long
been established as the industry standard. Rosemount
Analytical has combined this Hagan expertise with state of
the art features into one package - the World Class 3000
Oxygen Analyzer.
The World Class 3000 Analyzer is completely field repairable
as internal components are conveniently accessible for in-
house service personnel. The heater/thermocouple probe
assembly can be replaced and returned to service by in-
house personnel in one-half hour or less, without requiring
the probe tube to be removed from the process.
The World Class 3000 Analyzer offers flexible,
microprocessor-based electronics configurations with the
following components:
IFT 3000 Intelligent Field Transmitter (EExd II B T6)
HART
®
Model 275 Hand-Held Interface
MPS 3000 Multiprobe Test Gas Sequencer (safe area)
CRE 3000 Control Room Electronics (safe area)
HPS 3000 Field Interface Module (EExd II C T6)
The World Class Probe is CENELEC certified to EExd II B
T1 (370) and the junction box end of the probe is certified to
T6 (85). According to the certificate, the part with the
connection box may be used in areas classified T6.
The HART communications protocol allows instrument
technicians to interface with the IFT 3000 Intelligent Field
Electronics from the control room or any location where the
4-20 mA signal wires terminate. Service diagnostics and
calibrations can be performed without requiring plant
personnel to enter the often hot, inaccessible probe location.
For multiprobe applications, up to eight World Class 3000
probes can be connected to the CRE 3000 Control Room
Electronics. In addition to providing the same features as the
IFT 3000, the CRE 3000 averages the oxygen results,
reducing errors due to stratification.
Calibration data indicates the condition of the zirconium
oxide sensor cell. Analyzer calibration requires no special
equipment or knowledge and can be fully automated by
incorporating the MPS 3000 Multiprobe Test Gas Sequencer.
Cost is minimized and expansion is easy as the Multiprobe
Test Gas Sequencer is a modular design for one to four
World Class 3000 probes.
Rosemount Analytical also offers World Class 3000 Oxygen
Analyzer packages suitable for operation in non-hazardous
area locations. Please refer to product data sheet PD-106-
300 for more information.
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - Applications

Product Data SheetPDS 106-300NX.A01World Class 3000 November, 2000Visit our website at www.processanalytic.comOn-line ordering available. CENELEC

Pagina 2 - REPAIRABLE

Page 10CENELEC CERTIFIED WORLD CLASS 3000 WITH SAFE AREA IFTELECTRONICS — ORDERING INFORMATION (continued)(Cont’d)Code IFT 3000 Style11 Blind IF

Pagina 3 - OXYGEN PROBE

Page 11WORLD CLASS 3000 MULTIPROBE APPLICATION WITH CONTROLROOM ELECTRONICS (For Multi-Probe Applications)CRE 3000 Control Room Electronics M

Pagina 4 - COMMUNICATIONS

Page 12CRE 3000 CONTROL ROOM ELECTRONICSAmbient environment requirements: Clean, DryAmbient temperature range: 4° to 120°F (4° to 50°C)Vibrati

Pagina 5 - IFT 3000 SYSTEM DIAGRAM

Page 13CENELEC CERTIFIED WORLD CLASS 3000 WITH CONTROL ROOMELECTRONICS — ORDERING INFORMATION3001NCXCENELEC Certified World Class 3000 Oxygen An

Pagina 6 - Safe Area Enclosure

Page 14CENELEC CERTIFIED WORLD CLASS 3000 WITH CONTROL ROOMELECTRONICS ORDERING INFORMATION (CONTINUED)Special sensing cells are available for

Pagina 7

Page 15CENELEC CERTIFIED DIRECT REPLACEMENT PROBE UPGRADEPACKAGE — ORDERING INFORMATION3001DRXDirect Replacement CENELEC Certified World Class 3

Pagina 8

Page 16WORLD CLASS 3000 ACCESSORIESHPS 3000 FIELD INTERFACE ELECTRONICSÀÀ[For use with CRE 3000 or optional with IFT 3000 for probe electronics di

Pagina 9

Page 17WORLD CLASS 3000 ACCESSORIES (Continued)MPS 3000 MULTIPROBE TEST GAS SEQUENCER (OPTIONAL)ÀÀHousing classification: NEMA 4X (IP65)Humidity

Pagina 10 - ACCESSORIES

Page 18WORLD CLASS 3000 ACCESSORIES (Continued)O2 Test Gas KitsRosemount Analytical’s O2 Test Gas and Service Kits have been carefullydesigned to prov

Pagina 12

Page 2THE WORLD CLASS 3000 OXYGEN ANALYZER IS COMPLETELY FIELDREPAIRABLEDiffusion Element Assembly Sensor Cell Assembly Heater Thermocouple AssemblyOX

Pagina 13

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they ar

Pagina 14

Page 3WORLD CLASS 3000 OXYGEN ANALYZER DIMENSIONSOXYGEN PROBEÀÀHousing classification: CENELEC EExd IIB T1 (370)Probe lengths, nominal: 18 in. (

Pagina 15

Page 4WORLD CLASS 3000 ELECTRONICS CONFIGURATIONSA World Class 3000 analyzer package typically includesan oxygen sensing probe, signal conditionin

Pagina 16 - WORLD CLASS 3000 ACCESSORIES

Page 5FEATURES• Probe heater over-temperature protection uses softwareand hardware disable. With HPS 3000, hardware disablerequires optional cable.• O

Pagina 17

Page 6IFT 3000 INTELLIGENT FIELD TRANSMITTERHousing classification: CENELEC EExd IIB T6Humidity range: 95% Relative HumidityAmbient temperature

Pagina 18 - By-Pass Packages

Page 7CENELEC CERTIFIED WORLD CLASS 3000 WITH CENELEC-CERTIFIED IFTELECTRONICS — ORDERING INFORMATION3002NFXCENELEC Certified World Class 3000 Ox

Pagina 19

Page 8CENELEC CERTIFIED WORLD CLASS 3000 WITH CENELEC-CERTIFIED IFTELECTRONICS — ORDERING INFORMATION (continued)(Cont’d)Code IFT 3000 Style EEx

Pagina 20

Page 9CENELEC CERTIFIED WORLD CLASS 3000 WITH SAFE AREA IFTELECTRONICS — ORDERING INFORMATION3001NFXCENELEC Certified World Class 3000 Oxygen Ana

Commenti su questo manuale