Type A11 High Performance Butterfly Valve
Introduction 1...............................
Scope of Manual 1..........................
Description 1...............................
Specifications 3............................
Installation 3................................
Adjusting the Travel Stops 3.................
Preparing for Installation 4...................
Valve Orientation 4.........................
Installing the Valve 6........................
Thrust Washers 7.........................
Packing Adjustment and Shaft Bonding 7......
Maintenance 8..............................
Removing the Valve 9.......................
Packing Maintenance 9......................
Lantern Rings 10..........................
Lubrication Fittings and Purge Connectors 10.
Seal Maintenance 10........................
Soft Seal Installation 11....................
Metal and Phoenix III Seal Installation 11.....
Cryogenic Seal Installation 13...............
Valve Shaft/Disc Pin Unit Maintenance 13......
Gasket Retainer 15.........................
Bearing Maintenance 15.....................
Parts Ordering 16............................
Parts List 17................................
Introduction
Scope of Manual
This instruction manual includes installation,
maintenance, and parts information for Type A11
High Performance Butterfly Valves (figure 1) in Class
150, 300, and 600. For Class 900 and 1500 valves,
contact your Emerson Process Managementt sales
office.
For information about the actuator and accessories,
please refer to the separate instruction manuals for
these items.
Do not install, operate, or maintain a Type A11 valve
without first D being fully trained and qualified in
valve, actuator, and accessory installation,
operation, and maintenance, and D carefully reading
Figure 1. Type A11 Valve
W4642-1/IL
W4641-1/IL
and understanding the contents of this manual. If
you have any questions about these instructions,
contact your Emerson Process Management sales
office before proceeding.
Note
Neither Emerson, Emerson Process
Management, nor any of their affiliated
entities assumes responsibility for the
selection, use and maintenance of any
product. Responsibility for the
selection, use, and maintenance of any
product remains with the purchaser
and end-user.
Description
Type A11 High Performance Butterfly Valves are
available in either a flangeless wafer or a single
flange design, with a variety of seal, valve body, and
internal components. These valves feature a
dynamic sealing design that is used in a variety of
demanding applications.
Instruction Manual
Form 5338
February 2007
A11 Valve
Vedere la pagina 0
1 2 3 4 5 6 ... 23 24

Sommario

Pagina 1 - A11 Valve

www.Fisher.comD500073X012Type A11 High Performance Butterfly ValveIntroduction 1...Scope of Manual 1...

Pagina 2

A11 ValveInstruction ManualForm 5338February 200710HIGH PRESSUREAT SHUTOFFE0578 / ILFigure 5. SealsNOTES:THIS UNIDIRECTIONAL SEAL MUST BE INSTALLED SO

Pagina 3

A11 ValveInstruction ManualForm 5338February 200711CAUTIONIn the following step, use theappropriate tool to avoid damage tothe seal or T-slot area of

Pagina 4

A11 ValveInstruction ManualForm 5338February 200712Figure 6. Typical Seal Ring (Sectional)Figure 7. Typical Seal InstallationA5251/ILFor Phoenix III s

Pagina 5

A11 ValveInstruction ManualForm 5338February 200713CAUTIONIf a vise or other clamps are beingused, be sure damage is not done tothe flange gasket seal

Pagina 6

A11 ValveInstruction ManualForm 5338February 200714A5249/ILFigure 8. Packing ConfigurationsNoteThe disc must be removed from thewaterway side of the v

Pagina 7

A11 ValveInstruction ManualForm 5338February 200715Table 6. Torque Values for FastenersFastenerNominal SizeNSm InSlb FtSlb#10 4 35 - - -1/4 9 81 - - -

Pagina 8

A11 ValveInstruction ManualForm 5338February 20071622SOCKET HEAD CAP ORRETAINING RING SCREWS2RETAINING RING17GASKET9BACK-UP RING8SEAL RING16PACKING HE

Pagina 9

A11 ValveInstruction ManualForm 5338February 200717Parts ListAll items listed as being 3 through 24-inch are for theClass 600 valves only. The 30 thro

Pagina 10

A11 ValveInstruction ManualForm 5338February 200718ENVIRO-SEALr Packing PartsParts shown are used in standard and NACE constructions.100 Stud101 Hex N

Pagina 11

A11 ValveInstruction ManualForm 5338February 200719Key 8* Seal RingVALVE SIZE,INCHESCLASSMATERIALETFE Metal Seal Ring S31600Metal Seal Ring S17400H115

Pagina 12

A11 ValveInstruction ManualForm 5338February 20072Table 1. SpecificationsAvailable ConfigurationsValve SizesClass 150 and 300: Size J 30, J 36, J 42 a

Pagina 13

A11 ValveInstruction ManualForm 5338February 200720Keys 10* and 11* Bearing and Thrust BearingVALVE SIZE,INCHESCLASS QUANTITYBEARING MATERIALPEEK S316

Pagina 14

A11 ValveInstruction ManualForm 5338February 200721Key 14* Packing SetVALVE SIZE, INCHES CLASSMATERIALPTFE V-Ring Graphite Graphite with Oxygen Servic

Pagina 15

A11 ValveInstruction ManualForm 5338February 200722Key 19* Retainer Gasket (not shown)VALVE SIZE, INCHES CLASSMATERIALStandard ServiceSoft SealStandar

Pagina 16

A11 ValveInstruction ManualForm 5338February 200723Key 28*, Disc-Shaft-Pin Assembly(1) Square Connection [Disc (key 3), Shaft (key 4), Follower Shaft

Pagina 17

A11 ValveInstruction ManualForm 5338February 200724Emerson Process Management Marshalltown, Iowa 50158 USACernay 68700 France Sao Paulo 05424 BrazilS

Pagina 18

A11 ValveInstruction ManualForm 5338February 20073Table 3 Approximate Weight for Size 3 through 24-InchValvesVALVESIZECLASS 600Wafer Style Single Flan

Pagina 19

A11 ValveInstruction ManualForm 5338February 200741. To mount an actuator without travel stops, first, ifnecessary, remove the actuator from the valv

Pagina 20

A11 ValveInstruction ManualForm 5338February 20075Table 4. Stud Bolt and Cap Screw Data for Wafer Style ValvesClass 150 & Class 150/150VALVE SIZE,

Pagina 21

A11 ValveInstruction ManualForm 5338February 20076Figure 2. View of Stud BoltsE0179 / ILD In certain services (process fluids with highconcentrations

Pagina 22

A11 ValveInstruction ManualForm 5338February 20077Figure 3. Proper Installation ProcedureB2263/ILthe final bolting torque. Repeat this proceduresevera

Pagina 23

A11 ValveInstruction ManualForm 5338February 20078prevent shaft leakage. Excessive tightening ofpacking will accelerate wear and could producehigher r

Pagina 24

A11 ValveInstruction ManualForm 5338February 20079D Use lockout procedures to besure the above measures stay in effectwhile you work on the equipment.