Bulletin 71.1:CP200
2
Introduction
The CP200 Series pressure loaded regulators have
been engineered to  t a multitude of pressure reducing
applications including commercial and industrial
installations. The CP200 Series provides accurate
control for use in pressure factor measurement ( xed
factor billing) applications. This  exibility is provided
by the various body end connection sizes, outlet
pressure settings, and ori ce sizes.
Figure 2. Typical CP200 Series Cut-away View
VALVE DISK
LOWER
CASING
TYPE 67CP PRESSURE
LOADING REGULATOR
CLOSING
SPRING
DIAPHRAGM
DIAPHRAGM
HEAD
LEVER
ORIFICE
VALVE STEM
EXTERNAL
CONTROL LINE
PLUG (DO NOT
REMOVE IF UNIT IS
PRESSURIZED)
Overpressure Protection Options
Available:
Token Relief—Provides a small capacity or token
relief located in the Type 67CPR pressure loading
regulator that relieves minor overpressure caused by
thermal expansion or minor nicks in the ori ce or disk.
Secondary Seat™ Protection—Provides lockup
via a secondary seating and disk surface in the
event that damage to the primary disk or ori ce
seating surface, or debris in the  ow path, inhibit
primary lockup. Secondary Seat protection does
not provide additional overpressure protection in
the event the secondary seat or disk is damaged
by debris or contamination in the pipeline or from
conditions that would cause the regulator to go
wide open. See page 6 for additional information.