Types 627W and 627WH
D102504X012
Instruction Manual
Form 5447
March 2009
www.emersonprocess.com/regulators
Types 627W and 627WH Direct-Operated
Pressure Reducing Liquid Regulators
!
WARNING
Fisher
®
regulators must be installed,
operated, and maintained in accordance
with federal, state, and local codes,
rules and regulations, and
manufacturers instructions.
Installation, operation, and maintenance
procedures performed by unqualied
personnel may result in improper
adjustment and unsafe operation.
Either condition may result in
equipment damage or personal
injury. Use qualied personnel when
installing, operating, and maintaining
the Types 627W and 627WH regulators.
Introduction
Scope of the Manual
This Instruction Manual provides installation, startup,
adjustment, maintenance, and parts ordering
information for the Types 627W and 627WH pressure
reducing regulators for liquid service. Only personnel
qualied through training or experience should install,
operate, and maintain these regulators. If there are
any questions concerning these instructions, contact
your local Sales Ofce before proceeding.
Description
The Types 627W and 627WH (Figure 1) are direct-
operated pressure reducing regulators for liquid
service. On the internal registration version,
downstream pressure is registered internally through
the body to the underside of the diaphragm.
Types 627W and 627WH direct-operated regulators
are also available in a downstream control line version
for external pressure registration. The control line
version has a blocked throat with an O-ring stem
Figure 1. Types 627W and 627WH
Pressure Reducing Liquid Regulator
W4793
seal and a 1/4 NPT control line connection in the
diaphragm case. The stem seal separates the body
outlet pressure from the diaphragm case.
Specications
Refer to Specications lists for Types 627W and 627WH
constructions on page 2. Specications for a given
regulator as it originally comes from the factory are
stamped on the spring case nameplate.
Vedere la pagina 0
1 2 3 4 5 6 ... 11 12

Sommario

Pagina 1 - Types 627W and 627WH

Types 627W and 627WHD102504X012Instruction ManualForm 5447March 2009www.emersonprocess.com/regulatorsTypes 627W and 627WH Direct-Operated Pressure Red

Pagina 2

Types 627W and 627WH103633303124372346191514 17 16 11 12 10 139218454451835 34 32 29Figure 5. Type 627W Regulator Assembly34B7395APPLY LUBRICANTPARTS

Pagina 3

Types 627W and 627WH1136333024372346191514 17 16 11 12 10 139218454455018515229323435Figure 6. Type 627WH Regulator Assembly37B9752APPLY LUBRICANTPAR

Pagina 4 - Type 627W

Types 627W and 627WHThe Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective own

Pagina 5

Types 627W and 627WH21. The pressure/temperature limits in this Instruction Manual or any applicable standard limitation should not be exceeded.Spec

Pagina 6

Types 627W and 627WH3W6305-1DETAIL OF TYPE 627WH WITH INTERNAL DOWNSTREAM PRESSURE REGISTRATIONW6306-1DETAIL OF TYPE 627W WITH INTERNAL DOWNSTREAM PRE

Pagina 7

Types 627W and 627WH4!WARNINGPrinciple of OperationThe Type 627W or 627WH (refer to Figure 2) is a direct-operated regulator. On the internal registr

Pagina 8

Types 627W and 627WH5Table 2. Maximum Inlet Pressure, Differential Pressure, and Outlet Pressure RangesTYPE OUTLET PRESSURE RANGE, SPRING PART NUMBER

Pagina 9

Types 627W and 627WH6Table 3. Outlet Pressure RangesTYPESPRING RANGECOLOR SPRING PART NUMBERSPRING FREE LENGTH, INCHES (mm)SPRING WIRE DIAMETER, INCH

Pagina 10

Types 627W and 627WH7!WARNINGTable 6. Maximum Torque ValuesKEY NUMBER(1)DESCRIPTION FOOT POUNDS NEWTON METERS2 Orice 25 343 Cap Screw (with ductile

Pagina 11

Types 627W and 627WH8 5. Remove and inspect the stem O-ring (key 11) and replace if necessary. Also inspect and if necessary replace

Pagina 12

Types 627W and 627WH9Table 7. Body (Key 1)END CONNECTION STYLE BODY MATERIAL NPS 3/4 NPS 1 (DN 25) NPS 2 (DN 50)NPTDuctile Iron (Type 627W only) 30B3