Hydrastep Pressure Parts Unit Description
24675030 4-3
4.1 LOW PRESSURE ELECTRODES
These electrodes can be used for pressures of 50bar (725psi) for 459600802 units, and up to
120bar (1740psi) for 459600602 units - see Chapter 5 for Specifications. They are used with
the low pressure version of the Hydrastep water column shown in Figure 1.2 (in Chapter 1,
Part 2 of the manual).
Fitting instructions are supplied on the electrode package. Electrode details for this version
are shown in Figure 4.1.
Figure 4.1 - Low pressure electrode