Type MR105
3
Table 2. Outlet Pressure Range
Actuator Type
Spring Range
Spring Part
Number
Spring Color
Code
Spring Wire Diameter Spring Free Length
Maximum Pressure Over
Setpoint to Avoid Internal
Parts Damage
psig bar In. mm In. mm psig bar
Low Pressure
5 to 12 0.34 to 0.83 GE42909X012 White 0.437 11.1
9.70 246
20 1.4
10 to 24 0.69 to 1.6 GE42910X012 Silver 0.500 12.7
14 to 32 0.96 to 2.2 GE42911X012 Orange 0.562 14.3
18 to 43 1.2 to 3.0 GE43002X012 Red 0.625 15.9
High Pressure
25 to 60
(1)
1.7 to 4.1
(1)
GE42907X012 Green 0.375 9.52
120 8.3
43 to 100 3.0 to 6.9 GE42909X012 White 0.437 11.1
75 to 175
(2)
5.2 to 12.1
(2)
GE42910X012 Silver 0.500 12.7
110 to 300
(2)
7.6 to 20.7
(2)
GE42911X012 Orange 0.562 14.3
Actuator Type
Spring Range
Spring Part
Number
Spring Color
Code
Spring Wire Diameter Spring Free Length
Maximum Pressure Over
Setpoint to Avoid Internal
Parts Damage
psig bar In. mm In. mm psig bar
Low Pressure
5 to 8 0.34 to 0.55 GE42909X012 White 0.437 11.1
9.70 246
20 1.4
8 to 20 0.55 to 1.4 GE42910X012 Silver 0.500 12.7
12 to 30 0.83 to 2.1 GE42911X012 Orange 0.562 14.3
18 to 39 1.2 to 2.7 GE43002X012 Red 0.625 15.9
High Pressure
39 to 72 2.7 to 5.0 GE42909X012 White 0.437 11.1
120 8.3
71 to 175
(2)
4.9 to 12.1
(2)
GE42910X012 Silver 0.500 12.7
110 to 250
(2)
7.6 to 17.2
(2)
GE42911X012 Orange 0.562 14.3
1. NPS 2 / DN 50 body size spring range is limited to 45 psig / 3.1 bar.
2. Maximum setpoint is limited to 150 psig / 10.3 bar for constructions with Fluorocarbon (FKM) diaphragm.
BODY MATERIAL
END CONNECTION STYLE
Body Size
Cast Iron NPT, CL125 FF or CL250 RF CL125 FF or CL250 RF
WCC Steel
(1)(2)
NPT, CL150 RF, CL300 RF, CL600 RF
or PN 16/25/40 RF
CL150 RF, CL300 RF, CL600 RF
or PN 16 RF
CF8M Stainless Steel
(1)(2)
NPT, CL150 RF, CL300 RF, CL600 RF
or PN 16/25/40 RF
CL150 RF, CL300 RF, CL600 RF
or PN 16 RF
CF3M Stainless Steel
(1)(2)
NPT, CL150 RF, CL300 RF, CL600 RF
or PN 16/25/40 RF
CL150 RF, CL300 RF, CL600 RF
or PN 16 RF
1. Optional NACE construction available.
2. Constructions meet API 614 requirements.
Table 1. Body Size and End Connection Style
27.6 bar and temperatures up to 250°F / 121°C. Large
multi-purpose regulators provide fast, simple, reliable and
economical pressure control for a number of applications
and are suitable for different ow media such as liquid, air
and gas. In addition, the drain valve option allows you to
drain the system without expensive spool pieces saving
you time and space. Also, the bleed valve option allows
you to purge the air trapped underneath the diaphragm
when the high-pressure regulator is installed in the upright
position. Typical applications include lube oil, cooling
water and natural gas district stations.
!
WARNING
valve may result in regulator damage,
personal injury and property damage.
To avoid such injury and damage, make
certain the bleed valve (if used) is properly
closed after venting air or equivalent.
Always open bleed valves slowly. These
weepage will occur when the valves
are opened. Operating personnel must
protect themselves from exposure to
Principle of Operation
The Type MR105 is a direct-operated pressure
reducing regulator. Downstream pressure is registered
externally through a 1/2 NPT control line tapped in the
bonnet (for low-pressure actuator, see Figure 2) or in
the lower diaphragm casing (for high-pressure actuator,
see Figure 3). When downstream demand decreases,
the pressure under the actuator diaphragm increases.
This pressure overcomes the regulator setting (which
is set by the regulator control spring). Through the
action of the actuator stem and valve spring, the valve
plug moves closer to the seat ring and reduces the
ow. When demand downstream increases, pressure
under the actuator diaphragm decreases. Spring force
pushes the actuator stem downward, the valve plug
moves away from the seat ring and the ow increases
Commenti su questo manuale