Emerson USB Fieldbus Interface Manuale Utente

Navigare online o scaricare Manuale Utente per Networking Emerson USB Fieldbus Interface. Emerson USB Fieldbus Interface User`s manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - USB Fieldbus Interface

User's ManualAW7060MNL, Rev 2May 2014USB Fieldbus InterfaceUser's Manual

Pagina 2 - Contents

3 Software installation and device setupTopics covered in this chapter:• System requirements• Install the Fieldbus Interface Configuration utility• In

Pagina 3 - 1 Introduction

3.2 Install the Fieldbus Interface Configuration utilityNotes• Do not connect the USB Fieldbus Interface to the computer or to a fieldbus device or se

Pagina 4 - 1.1 Safety message

3.3 Install the Communication DTM software1. Insert the USB Fieldbus Interface installation CD into the CD drive of yourcomputer.2. Navigate to the Em

Pagina 5 - 2 USB Fieldbus Interface

Emerson DTM Library installationFigure 3-3: 5. Click Close when done.May 2014 User's Manual13

Pagina 6 - Box contentsFigure 2-1:

3.5 Setup and connectionNoteInstall the Fieldbus Interface Configuration utility first before setting up and connecting the USBFieldbus Interface. For

Pagina 7 - 2.2 Parts and function

Sample benchtop connectionFigure 3-4: 3.6 Connect to a live fieldbus segmentWARNING!Do not use the Provide Power option on the Fieldbus Interface Co

Pagina 8

4 Fieldbus Interface Configuration utilityTopics covered in this chapter:• Launch the Fieldbus Interface Configuration utility• Power fieldbus devices

Pagina 9 - 2.3 Power modes

4.2 Power fieldbus devicesYou can power a fieldbus device or segment by connecting it to an externalpower source or by using the Fieldbus Interface Co

Pagina 10 - 3.1 System requirements

4.3 Commission fieldbus devicesCommissioning sets the fieldbus device address to a valid permanent addressand sets the device tag to a valid string.No

Pagina 11 - May 2014 User's Manual

CommissionFigure 4-3: NoteThe commissioning process takes about 1 to 2 minutes to complete.6. Repeat steps 2 through 5 for each device you want to c

Pagina 12 - User's Manual May 2014

Copyright© Emerson Process Management, 2014. All rights reserved. Printed in the USA.TrademarksThe Emerson logo is a trademark and service mark of Eme

Pagina 13 - 5. Click Close when done

DecommissionFigure 4-4: 4. Determine if the fieldbus device was commissioned on another host,then select Yes or No.• If you choose Yes, the decommis

Pagina 14 - 3.5 Setup and connection

NoteOnly the device class of a commissioned fieldbus device can be identified. For moreinformation on commissioning a device, see Section 4.3.Identify

Pagina 15 - WARNING!

Change the device classFigure 4-6: 5. Click Yes to acknowledge the restart of the device.6. Click OK to continue.NoteChanging the device class takes

Pagina 16

Start Server/Stop ServerFigure 4-7: NoteThe USB FF HSE Server should be running in order to use the Fieldbus Interface Configurationutility to power

Pagina 17 - 4.2 Power fieldbus devices

5 Using with AMS Device ManagerTopics covered in this chapter:• Add a network component in AMS Device Manager• Configure fieldbus devices in AMS Devic

Pagina 18

Add a network componentFigure 5-1: 3. Select the FF HSE Network component, and click Install.May 2014 User's Manual25

Pagina 19

Install an FF HSE network componentFigure 5-2: 4. Click Next to proceed.5. Enter a name for the FF HSE network, and click Next.User's Manual Ma

Pagina 20 - 4.5 Change the device class

Enter a network nameFigure 5-3: 6. Choose to automatically discover FF HSE linking devices or manuallyconfigure IP addresses for FF HSE linking devi

Pagina 21

Configure the network connectionFigure 5-4: Notes• Choosing the PC NIC address in the Primary HSE NIC Address field displays the USB FieldbusInterfa

Pagina 22

7. Click Finish when done.5.2 Configure fieldbus devices in AMS Device ManagerNoteCommission fieldbus devices first in the Fieldbus Interface Configur

Pagina 23

1 IntroductionThis manual guides you in using the USB Fieldbus Interface (interface) topower and/or configure fieldbus devices. Included here are basi

Pagina 24

Scanning synchronizes the AMS Device Manager database withconnected live devices.6. Right-click the fieldbus device you want to configure and select f

Pagina 25

For more information about the context menus and other AMS DeviceManager functions, refer to AMS Device Manager Books Online.May 2014 User's Manu

Pagina 26 - 4. Click Next to proceed

6 Using with an FDT Frame ApplicationTopics covered in this chapter:• Install an FDT Frame Application• Update the DTM library• Configure fieldbus dev

Pagina 27

Update device catalogFigure 6-1: 3. Click Yes when prompted to create a new PACTware device catalog.4. Close the device catalog when done.6.3 Config

Pagina 28

Project paneFigure 6-2: Press F2 to display the Project pane if it is not already displayed.3. Select Emerson FF HSE Server and click OK.Add the Eme

Pagina 29

FF HSE Server - Add deviceFigure 6-4: 5. Select Emerson USB Fieldbus Interface and click OK.May 2014 User's Manual35

Pagina 30

Add the Emerson USB Fieldbus InterfaceFigure 6-5: 6. Right-click USB Fieldbus Interface on the Project pane and click Add device.User's Manual

Pagina 31

USB Fieldbus Interface - Add deviceFigure 6-6: 7. Select the device you want to add then click OK.May 2014 User's Manual37

Pagina 32 - 6.2 Update the DTM library

Add deviceFigure 6-7: Only devices with DTMs available and installed appear on the list. Formore information on DTM library installation, see Sectio

Pagina 33

Edit DTM AddressFigure 6-8: 9. On the right pane, select the fieldbus device from the list, enter thedevice address in the Node ID field, and click

Pagina 34 - Project paneFigure 6-2:

1.1 Safety messageWARNING!Do not connect the USB Fieldbus Interface to a live segment (with an active DCS Host and powersupply attached) if the power

Pagina 35

NoteThe device address and Node ID should match. The device address is set and can be found inthe Fieldbus Interface Configuration utility. For more i

Pagina 36

ParameterFigure 6-11: This displays the various parameters you can edit for the device.12. Configure the parameters of the device.NoteThe parameter

Pagina 37

Edit device parametersFigure 6-12: User's Manual May 201442

Pagina 38

7 TroubleshootingTopics covered in this chapter:• Fieldbus device not responding in AMS Device Manager• Fieldbus device not detected in Fieldbus Inter

Pagina 39 - Enter Node IDFigure 6-9:

Commissioned fieldbus devices appear with their own icons in AMS DeviceManager and are characterized by a valid permanent address or by a validdevice

Pagina 40

No device detected dialogFigure 7-3: Click OK and check for the following:• Make sure the fieldbus device or segment is powered either by an externa

Pagina 41 - ParameterFigure 6-11:

7.3 Cannot edit device parameters in FDT Frame ApplicationCannot edit device parameters in PACTwareFigure 7-4: • Check the Node ID in PACTware and t

Pagina 42

Appendix AApprovals and certificationsFieldbus Foundation CommunicationFF Physical Layer Specification (IEC 61158-2)FF Physical Layer Conformance Test

Pagina 43 - 7 Troubleshooting

Appendix BSpecificationsSoftwareSupported operating systemsWindows 8.0 and 8.1Windows 7 (32- or 64-bit)Windows XP Home or Professional (32-bit) SP3USB

Pagina 44 - Configuration utility

Appendix CWaste disposalProducts with the following label comply with the Waste Electrical andElectronic Equipment (WEEE) directive, 2002/96/EC, which

Pagina 45

2 USB Fieldbus InterfaceTopics covered in this chapter:• Overview• Parts and function• Power modes2.1 OverviewThe USB Fieldbus Interface enables two-w

Pagina 46

Appendix DInstall drivers manuallyNotes• If you have previously installed a pre-release version of drivers, follow the procedure in Appendix F first b

Pagina 47 - Appendix A

Found New Hardware Wizard - Select driver locationFigure D-1: 5. Browse to where the drivers are located and click Next.The drivers are typically in

Pagina 48 - Appendix B

Found New Hardware Wizard - Select best driver matchFigure D-2: If you want to verify the proper installation of drivers, open Windows DeviceManager

Pagina 49 - Appendix C

Windows Device ManagerFigure D-3: May 2014 User's Manual53

Pagina 50 - Appendix D

Appendix EDisable driver signature enforcement in Windows8.0 and 8.11. Open the Windows 8 Charms bar.2. Click Settings > Change PC settings.3. From

Pagina 51

Appendix FRemove pre-release driver versions on a WindowsXP operating system1. Click Start > Control Panel > Add or Remove Programs.2. Select 77

Pagina 52

Advanced Settings for COMxx dialogFigure F-1: 10. Click OK to close the Properties dialog.User's Manual May 201456

Pagina 53

IndexAAMS Device Manageradding network component 24using to configure fieldbus devices 29Cchange the device class 20commission fieldbus devices

Pagina 54 - Appendix E

power indicator light status 7power modes 9Provide Power 17Rremove pre-release driver versions 55Ssetup and connectionbenchtop/segment connect

Pagina 55 - Appendix F

User's ManualPart Number: AW7060MNL, rev. 2May 2014Emerson Process Management12001 Technology DriveEden Prairie, MN 55344 USAT 1(952)828-3633F 1(

Pagina 56

The USB Fieldbus Interface comes with a USB cable, lead set, user's manual*,and installation CD*.Box contentsFigure 2-1: User's Manual May

Pagina 57

2.2 Parts and functionUSB Fieldbus InterfaceFigure 2-2: 1 Field connection indicator light (*)Indicates the fieldbus device connection status2 Power

Pagina 58

Indicator light scenariosTable 2-1: PowerindicatorlightFieldconnectionindicator lightScenariosNormal scenariosGreen GreenThe USB Fieldbus Interface

Pagina 59

2.3 Power modesThe USB Fieldbus Interface is capable of working in two power modes:• Mode 1 - The interface does not supply power to the connected fie

Commenti su questo manuale

Nessun commento