Emerson FM-3 Guida Utente Pagina 29

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 263
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 28
10
Epsilon Eb and EN Drives Reference Manual
negative changes to the Pulse Position Input. All edges of A and B are counted, therefore one
revolution of a 2048 line encoder will produce an 8192 count change on the Pulse Position
Input.
Figure 5: Pulse/Quadrature Signals, + Command
Figure 6: Pulse/Quadrature Signals, – Command
Pulse/Pulse Interpretation
In Pulse/Pulse interpretation, pulses received on the A channel are interpreted as positive
changes to the Pulse Position Input. Pulses received on the B channel are interpreted as
negative changes to the Pulse Position Input.
Figure 7: Pulse/Pulse Signals, Differential Inputs
Vedere la pagina 28