Quick Start Guide
N6 CSA Class I Division 2
Certificate: 2646342
Standards Used: CSA Std. C22.2 No. 0-10, CSA Std. C22.2 No. 213 - M1987,
CSA Std. C22.2 No.61010-1-12, ANSI/ISA 12.12.01-2012, ANSI/ISA
61010-1-2012
Markings: SUITABLE FOR CL I, DIV. 2, GP A, B, C, D
Temperature code: T4 (-40 °C
T
a
70 °C)
Note
Shall be powered by a class 2 power supply.
Suitable for dry indoor locations only.
Equipment must be installed in a suitable tool accessible enclosure subject to the end
use application.
Using the 1410D and the Smart Wireless Field Link 781 in a hazardous location requires
barriers between the two units.