Square and level the template(s) on the stakes so the tops of the mounting plates
are flush with, or no more than 0.25" (
1
/
4
-in). (6 mm) above, the top of the pad
(Fig. 11). Square the template(s) so the diagonal measurement between the
anchor bolts is equal.
18.00"
35.31" REF
48.00” REF
24.00"
28.00"
6.00”
6.00”
7.70”
.80”
3.50”
3.50”
3.50”
1.25”
2.50”
Fig. 10 : Foundation Pad Design with Customer Conduit Location